Početna Biblioteka 2022 Clinical evaluation of one-step impression technique and def…

Clinical evaluation of one-step impression technique and definitive casts

Özcan Işıl · Köroğlu Aslıhan · Kale Ediz · Özçelik Tuncer Burak · Yilmaz Burak

Rad u časopisuBalkan Journal of Dental Medicine, 26(2), 2022, str. 82–87

Sažetak

Background/Aim: The purpose of this study was to evaluate the quality of impressions made with vinyl polysiloxane (VPS) material in clinical conditions by using the one-step impression technique, and the quality of casts generated from these impressions. The effect of operator, number and location of abutments, and presence of bleeding were also investigated. Material and Methods: A total of 150 fixed dental prosthesis (FDP) impressions were taken and considered acceptable by 3 experienced prosthodontists in a clinic in an institutional setting. The impressions were evaluated and rated by another experienced prosthodontist and respective casts were evaluated and rated by an experienced dental technician using a digital microscope with ×200 magnification. The defects observed were noted as bubbles, voids, tears, or other defects. A scale was structured for the impressions and casts with ratings of Alpha (excellent; no defects), Bravo (acceptable; small defects), Charlie (inadequate; defects that require remaking of impression), and Delta (unacceptable; substantial defects at preparation finish lines). The data were analyzed with the Chi-square test for inter-operator, number of abutments, and location of prepared tooth variables (a=0.05). Results: The scale ratings were 85 Alpha (57%), 52 Bravo (34%), 6 Charlie (4%), and 7 Delta (5%) for the impressions, and 81 Alpha (54%), 58 Bravo (39%), 4 Charlie (3%), and 7 Delta (5%) for the respective casts. Sixty-nine percent of the impressions and respective casts were rated with the same score. The scale rating results were not influenced by inter-operator variability or number of abutments. Location of the prepared tooth was significant for anterior/posterior (p=0.04), but was not significant for maxilla/ mandible (p>0.05). Bleeding at the preparation site had a significant effect on the acceptability of the impression (p=0.003). Conclusions: The acceptability of VPS impressions using onestep technique was independent of the operator, number of abutments, or whether the prepared tooth was in maxilla or mandible. Impressions of teeth in the anterior region were more acceptable than those located in the posterior. Bleeding negatively affected the acceptability of the impressions. Clinicians may use VPS impressions for the fabrication of FDPs using onestep dual-phase technique. However, clinicians should carefully evaluate their impressions when bleeding is present when using this technique.

dental impression techniquedental impression materialsvinyl polysiloxaneimpression qualityfixed dental prostheses
Izvor i prava

Objavljeno u Balkan Journal of Dental Medicine pod licencom CC BY. Autorska prava zadržavaju autori.

Zapis časopisa u DOAJ-u (ISSN 2738-0807), provereno 28.09.2026.

Verzija od zapisa kod izdavača
Kako citirati: Özcan Işıl, Köroğlu Aslıhan, Kale Ediz, Özçelik Tuncer Burak, Yilmaz Burak. Clinical evaluation of one-step impression technique and definitive casts. Balkan Journal of Dental Medicine. 2022;26(2):82-87. doi:10.5937/bjdm2202082Q

Autori

Özcan Işıl

Başkent University Faculty of Dentistry, Department of Prosthodontics, Ankara, Turkey

Köroğlu Aslıhan

Fatma Kemal Timuçin Oral and Dental Health Hospital, Adana, Turkey

Kale Ediz

Private Dental Practice, Adana, Turkey

Özçelik Tuncer Burak

Başkent University Faculty of Dentistry, Department of Prosthodontics, Ankara, Turkey

Yilmaz Burak

University of Bern, School of Dental Medicine, Department of Reconstructive Dentistry and Gerodontology, Bern, Switzerland