Početna Biblioteka 2017 Diode Laser Irradiation in Endodontic Therapy through Cycles…

Diode Laser Irradiation in Endodontic Therapy through Cycles - in vitro Study

Trišić Dijana · Ćetenović Bojana · Jovanović Igor · Gjorgievska Elizabeta · Popović Branka · Marković Dejan

Rad u časopisuBalkan Journal of Dental Medicine, 21(2), 2017, str. 108–111

Sažetak

Background/Aim: The aim of this in vitro study was to investigate the influence of irradiation cycles and resting periods, on thermal effects on the external root surface during root canal irradiation of two diode laser systems (940 nm and 975 nm), at output powers of 1 W and 2 W in continuous mode. In previous studies the rising of temperature above 7°C has been reported as biologically accepted to avoid periodontal damage on the external root surface. Material and Methods: Twenty human inferior incisors were randomly distributed into four groups, the 940 nm, and the 975 nm diode laser irradiation, both with an output power of 1 W and 2 W, in continuous mode. The thermographic camera was used to detect temperature variations on the external root surface. Digital radiography of the samples was made. Results: After three cycles of irradiation, at apical third of the root, mean temperature variation by 940 nm diode laser irradiation was 2.88°C for output power of 1 W, and 6.52°C for output power of 2 W. The 975 nm laser caused a higher temperature increase in the apical region, with temperature variation of 13.56°C by an output power of 1 W, and 30.60°C at 2 W, with a statistical significance of p ≤ 0.0001 between two laser systems compared for the same power. The resting periods of 20 s between cycles were enough to lower temperature under 7°C in the case of 1 W and 2 W for 940 nm diode laser, while for 975 nm laser, after three irradiation cycles overheating occurred at both output power rates. Conclusion: Three cycles irradiation of 940 nm diode laser, with resting periods of 20 seconds, allowed safe usage of 1 W and 2 W in CW for endodontic treatment. For 975 nm at a power rate of 1 W, the last resting period drop the temperature near the safe limit and it came under 7°C in a period less than a minute, while at the power of 2 W the resting periods were not long enough for the safe temperature decrease.

diode laserendodonticsbactericidaltemperature variationsexternal root surface
Izvor i prava

Objavljeno u Balkan Journal of Dental Medicine pod licencom CC BY. Autorska prava zadržavaju autori.

Zapis časopisa u DOAJ-u (ISSN 2738-0807), provereno 28.09.2026.

Verzija od zapisa kod izdavača
Kako citirati: Trišić Dijana, Ćetenović Bojana, Jovanović Igor, Gjorgievska Elizabeta, Popović Branka, Marković Dejan. Diode Laser Irradiation in Endodontic Therapy through Cycles - in vitro Study. Balkan Journal of Dental Medicine. 2017;21(2):108-111. doi:10.1515/bjdm-2017-0016

Autori

Trišić Dijana

Clinic for Paediatric and Preventive Dentistry, Faculty of Dental Medicine, University of Belgrade, Belgrade, Serbia

Ćetenović Bojana

Clinic for Paediatric and Preventive Dentistry, Faculty of Dental Medicine, University of Belgrade, Belgrade, Serbia

Jovanović Igor

Department of Electronics, Faculty of Electronic Engineering, University of Niš, Niš, Serbia

Gjorgievska Elizabeta

Faculty of Dentistry, University “Ss Cyril and Methodius” Skopje, Skopje, FYRM, Macedonia

Popović Branka

Institute of Human Genetics, Faculty of Dental Medicine, University of Belgrade, Belgrade, Serbia

Marković Dejan

Clinic for Paediatric and Preventive Dentistry, Faculty of Dental Medicine, University of Belgrade, Belgrade, Serbia