Početna Biblioteka 2024 Evaluation of the influence of polymerization light intensit…

Evaluation of the influence of polymerization light intensity, irradiation time, and source distance on the depth of cure of resin based composite

Duratbegović Damir · Kobašlija Sedin · Jakupović Selma · Pervan Nedim · Hodžić Damir · Katana Elma · Jakupović Senka

Rad u časopisuBalkan Journal of Dental Medicine, 28(3), 2024, str. 190–199

Sažetak

Background/Aim: To evaluate the effect of curing light parameters (intensity, duration, and distance of curing tip) on the depth of cure of conventional resin-based composite. Material and methods: Cylindrical specimens made of nanohybride resin-based composite are cured with 12 different curing protocols, combined with 3 different light intensities (300, 650, and 1100 mW/cm²), 2 distances of curing tip (0 and 8 mm), and 2 exposure times (20 and 40 seconds). The specimens were measured after scraping the uncured composite material according to the ISO 4049 standard. The depth of cure was calculated by dividing the length of the remaining composite by 2. Data were analyzed using: Levene's test and Multivariate Analysis-of-variance (MANOVA). The level of significance was set at P<0.05. Results: The highest depth of cure (3.332 mm) was observed for curing protocol 1100mW/cm²/0mm/40s. The lowest depth of cure had specimens cured with curing protocol 300 mW/cm²/8mm/20s (2.034mm). MANOVA showed a significant influence of the distance of the curing tip (P=0.014; P=0.001) regardless of light intensity and duration of exposure time. Exposure time was a significant factor (P=0.009) when cured from different distances. Although higher light intensity produced a higher depth of cure, light intensity was not a significant factor. Conclusions: The depth of cure can be increased by reducing the distance of the curing tip, when it is possible. At a distance of 8 mm, the depth of cure can be increased by a longer exposure time, regardless of curing light intensity.

resin-based compositespolymerizationlight curingdepth of cureiso 4049distance of curing tipexposure timelight intensity
Izvor i prava

Objavljeno u Balkan Journal of Dental Medicine pod licencom CC BY. Autorska prava zadržavaju autori.

Zapis časopisa u DOAJ-u (ISSN 2738-0807), provereno 28.09.2026.

Verzija od zapisa kod izdavača
Kako citirati: Duratbegović Damir, Kobašlija Sedin, Jakupović Selma, Pervan Nedim, Hodžić Damir, Katana Elma, Jakupović Senka. Evaluation of the influence of polymerization light intensity, irradiation time, and source distance on the depth of cure of resin based composite. Balkan Journal of Dental Medicine. 2024;28(3):190-199. doi:10.5937/bjdm2403190D

Autori

Duratbegović Damir

University of Sarajevo, Faculty of Dentistry with Dental Clinical Center, Department of Pediatric and Preventive Dentistry, Sarajevo, Bosnia and Herzegovina

Kobašlija Sedin

University of Sarajevo, Faculty of Dentistry with Dental Clinical Center, Department of Pediatric and Preventive Dentistry, Sarajevo, Bosnia and Herzegovina

Jakupović Selma

University of Sarajevo, Faculty of Dentistry with Dental Clinical Center, Department of Dental Pathology with Endodontics, Sarajevo, Bosnia and Herzegovina

Pervan Nedim

University of Sarajevo, Faculty of Mechanical Engineering, Sarajevo, Bosnia and Herzegovina

Hodžić Damir

University of Sarajevo, Faculty of Mechanical Engineering, Sarajevo, Bosnia and Herzegovina

Katana Elma

University of Sarajevo, Faculty of Dentistry with Dental Clinical Center, Department of Pediatric and Preventive Dentistry, Sarajevo, Bosnia and Herzegovina

Jakupović Senka

University of Sarajevo, Faculty of Dentistry with Dental Clinical Center, Department of Pediatric and Preventive Dentistry, Sarajevo, Bosnia and Herzegovina