Hydration reaction analysis of calcium-silicatebased materials using scanning electron microscopy and X-ray diffraction method
Mutluay Abidin Talha · Mutluay Merve · Pehlivanli Adem
Rad u časopisuBalkan Journal of Dental Medicine, 26(3), 2022, str. 133–141
Sažetak
Background/Aim: The components of calcium silicate-based materials can be identified through X-Ray Diffraction Analysis. This study aimed to determine the hydration reactions and particle size of MTA Angelus, Biodentine, and NeoMTA Plus as calcium-silicate-based materials. Material and Methods: The powder and set cement samples using divergence and scatter slits of 1○ and a receiver slit of 0.10 mm. The scanning range was set at 5○ to 70○, and ongoing scans for the theta-2theta range was performed with a scan speed of 2○/minute (-1). The patterns obtained were analyzed using search-match software. The three most substantial peaks were used to identify hydration reactions and major crystalline structures. Also, Scanning Electron Microscope (SEM) analysis was performed and the particle size of set materials were determined using an image analysis software. Results: According to X-Ray Diffraction Analysis, the main components were determined as tricalcium silicate and dicalcium silicate in the three calcium silicate-based materials. We determined that the main components of the materials were similar. We also identified the extensive presence of tricalcium aluminate in MTA Angelus, calcium carbonate in Biodentine, and calcium phosphate salts in NeoMTA Plus. Furthermore, the results of the present particle analysis show that the calcium-silicate-based materials' distribution of particle count and size varies. Biodentine has the widest, and MTA Angelus has the narrowest particle size distribution range. NeoMTA Plus has the largest number of fine, large-sized particles (p < 0.0001), while MTA Angelus and Biodentine have a more homogeneous and nonstatistically significant particle distribution range (p > 0.05). Conclusions: The present findings provide insight into variations in performance between different calcium-silicate-based materials.
Objavljeno u Balkan Journal of Dental Medicine pod licencom CC BY. Autorska prava zadržavaju autori.
Zapis časopisa u DOAJ-u (ISSN 2738-0807), provereno 28.09.2026.
Verzija od zapisa kod izdavačaAutori
Kirikkale University, Vocational School of Health Services, Department of Dental Hygiene, Kirikkale, Turkey
Kirikkale University, Vocational School of Health Services, Department of Dental Hygiene, Kirikkale, Turkey
Kirikkale University, Vocational School of Health Services, Department of Medical Imaging, Kirikkale, Turkey
Srodni radovi
Po zajedničkim ključnim rečima.
Sealing Efficiency of MTA, Accelerated MTA, Biodentine and RMGIC as Retrograde Filling Materials (2021) In Vitro Biocompatibility of Nanostructured Endodontic Materials Using SCAP Cells (2017) Endodontic and Prosthetic Management of a Mid-Root and Crown Fracture of a Maxillary Central Incisor (2014)